Practice HVAC Licensing Exam
(Answers at end of exam)
- A tracer wire buried with plastic gas piping shall be minimum ___AWG
- a) 16
- b) 14
- c) 18
- d) 20
- The minimum ventilation rate for living area of a residence is the greater of 15 cfm per person or ____ air changes per hour
- a) .5
- b) .35
- c) .40
- d) 1
- When using a test pressure of 10 psig, the test gauge shall not be capable of reading pressures greater than _____PSIG
- a) 100
- b) 80
- c) 50
- d) 75
- The use of gypsum boards to for plenums shall be limited to systems where the temperature does not exceed _______ degrees F and the temperature of the conveyed air is kept above the dew point
- a) 125
- b) 110
- c) 250
- d) 95
- A sauna room shall have a vent opening above the door at least 4 inches by ____ inches
- a) 6
- b) 12
- c) 10
- d) 8
- Gas piping shall be labeled at intervals not exceeding ______ feet
- a) 8
- b) 5
- c) 4
- d) 3
- A JOINT OBTAINED BY THE JOINING OF METAL PARTS WITH METALLIC MIXTURES OF ALLOYS WHICH MELT AT 1050 DEGREES F, IS CALLED A __________ JOINT.
- a) WELDED
- b) MECHANICAL
- c) BRAZED
- d) SOLDERED
- If an 6″ X 10″ duct is terminated with a metal louver (75% free area), the louver must be a minimum _____ square inches
- a) 90
- b) 60
- c) 120
- d) 80
- A gas regulator that reduces incoming pressure between .5 and 5 psig to a lower pressure is called a __________.
- a) service entrance regulator
- b) low pressure regulator
- c) high pressure regulator
- d) medium pressure regulator
- Unless otherwise specified by the manufacturer, vents shall terminate not less than ______feet above the highest connected appliance
- a) 12
- b) 10
- c) 8
- d) 5
- When obtaining combustion air from a crawl space, the free area of the crawl space vent to the outside must be a minimum ________ the size of the combustion air opening
- a) 4 times
- b) 2.5 times
- c) 3 times
- d) 2 times
- A type I hood, 5 foot long, wall mounted canopy, serving medium-duty appliances shall have a minimum capacity of _____ CFM
- a) 1000
- b) 2500
- c) 500
- d) 1500
- Downdraft kitchen exhaust ducts may be constructed of______.
- a) all of the above
- b) sheet metal
- c) aluminum
- d) PVC
- When combustion air is mechanically forced into a room, containing appliances with a total input rating of 150,000 btuh. The required ventilation equipment must be rated a minimum of __________ CFM.
- a) 350
- b) 52.5
- c) 150
- d) 75.5
- The maximum cfm of duct leakage allowed with a air handler in place for a 1500 square foot home with .1 inch w.c. is____.
- a) 75
- b) 150
- c) 60
- d) 80
- LP gas plastic pipe shall not be operated at pressures greater than ______ psig.
- a) 100
- b) 15
- c) 30
- d) 10
- Semi-ridged metallic tubing used as appliance connectors shall not exceed ___ feet
- a) 8
- b) 3
- c) 6
- d) 5
- For other than appliances installed in fireplaces, a gas shutoff valve shall be located within ___feet of the appliance
- a) 3
- b) 4
- c) 10
- d) 6
- Appliance pits greater than 12 inches deep shall be lined with masonry extending ___inches above the adjoining grade
- a) 4
- b) 2
- c) 3
- d) 6
- Gas piping may be joined in concealed locations using which of the following methods?
- a) brazing
- b) compression fittings
- c) unions
- d) swing joints
- 1/2″ copper tubing must be supported a minimum of _______ feet when installed horizontally
- a) 4
- b) 10
- c) 8
- d) 6
- Equipment, appliances or material included in a list published by a nationally recognized testing laboratory concerned with product evaluation and states that the above item meets recognized standards is said to be _____________
- a) approved
- b) listed
- c) certified
- d) tested
- A type I hood is not required for _______>
- a) griddles
- b) hot dog cookers
- c) fryers
- d) broilers
- REFRIGERANTS REMOVED FROM A SYSTEM IN ANY CONDITION WITHOUT NECESSARILY TESTING OR PROCESSING THEM ARE CALLED___________.
- a) RECYCLED REFRIGERANTS
- b) RECIEVED REFRIGERANTS
- c) RECOVERED REFRIGERANTS
- d) RECLAIMED REFRIGERANTS
- THE MAXIMUM ALLOWABLE HORIZONTAL LENGTH OF A CATEGORY I APPLIANCE SINGLE WALL VENT CONNECTOR IS _______% OF THE HEIGHT OF THE VENT
- a) 50
- b) 25
- c) 75
- d) 100
- A commercial stainless-steel duct must be constructed of ______ gage thickness
- a) 20
- b) 14
- c) 18
- d) 16
- A NON-LOAD BEARING STUD MAY BE NOTCHED ______% OF ITS DEPTH.
- a) 30
- b) 40
- c) 25
- d) 15
- CATEGORY I GAS EQUIPMENT MAY BE VENTED WITH WHICH OF THE FOLLOWING TYPES OF VENTS?
- a) ALL THE ABOVE
- b) CHIMNEY WITH CLAY LINER
- c) TYPE B
- d) SINGLE WALL METAL
- RECLAIMED REFRIGERANTS SHALL NOT BE REUSED IN A DIFFERENT OWNERS EQUIPMENT UNLESS TESTED AND FOUND TO MEET THE PURITY REQUIREMENTS OF
- a) ARI 700
- b) ASTM A53
- c) NFPA 54
- d) ASHRAE 34
- IF A GALLON OF OIL CONTAINING 140,000 BTU’S SELLS FOR $1.25, HOW MUCH WILL 1,000,000 BTU’S COST WHEN USED IN AN 80% AFUE OIL FURNACE
- a) $8.93
- b) $11.16
- c) $14.00
- d) $12.78
- For 3/4 inch steel gas pipe, hangers or supports shall be spaced not farther than _____feet apart
- a) 10
- b) 4
- c) 8
- d) 6
- An auxiliary drain pan must have a minimum depth of ____ inche/s
- a) 1.5
- b) 1
- c) 1.25
- d) 2
- A 12″ ROUND DUCT HAS A RECTANGULAR EQUIVALENT OF
- a) 16 X 8
- b) 15 X 8
- c) 14 X 8
- d) 17 X 8
- GAS APPLIANCE CONNECTORS SHALL NOT PASS THROUGH ANY OF THE FOLLOWING EXCEPT
- a) WALLS
- b) CEILINGS
- c) FACTORY BUILT FIREPLACES
- d) FLOORS
- Sauna heaters shall have a thermostat that limits the room temperature to _______ degrees F
- a) 194
- b) 144
- c) 114
- d) 120
- The minimum R value of duct insulation installed in UNCONDITIONED ATTICS IS _____.
- a) R 5
- b) R 6
- c) R 8
- d) R 4
- ___________ piping may only be used for gas piping outside and underground.
- a) Aluminum
- b) Copper
- c) Steel
- d) Plastic
- The maximum length allowed for a 4-inch dryer duct with two 90 degree bends is ______ feet
- a) 25
- b) 35
- c) 30
- d) 40
- The minimum return opening to an 80,000 btuh (output rating) forced air furnace shall be _____ square inches. (not a code requirement for 2018 and earlier codes)
- a) 160
- b) 80
- c) 140
- d) 100
- A location that cannot be accessed without damaging permanent parts of a building is called a/an _____ location
- a) inaccessible
- b) assessible
- c) concealed
- d) ready access
- AN APPLIANCE RATED AT 75,000 BTUH INPUT MUST BE PLACED IN A ROOM CONTAINING A MINIMUM ______ CUBIC FEET, IF IT DOES NOT RECEIVE COMBUSTION AIR FROM OUTDOORS.
- a) 3750
- b) 7500
- c) 1500
- d) 75000
- A FUEL FIRED FURNACE, MEASURING 22 CUBIC FEET MUST BE PLACED IN A ROOM GREATER THAN __________ CUBIC FEET IF IT IS NOT APPROVED FOR CLOSET INSTALATION. (not a code requirement for 2018 and earlier codes)
- a) 264
- b) 352
- c) 220
- d) 564
- The ignition source of an appliance shall be elevated not less than _____ unless it is listed as flammable ignition resistant
- a) 6 feet
- b) 18 inches
- c) 4 feet
- d) 24 inches
- Transition ducts used to connect commercial dryers to exhaust duct shall be limited to ___ feet in length
- a) 4
- b) 3
- c) 6
- d) 8
- A label shall be affixed to a gas appliance with all the following information except _______
- a) BTUH rating
- b) manufacture date
- c) type of fuel used
- d) minimum clearances
- The miminum size supply line to an oil furnace shall be _______ inch.
- a) 1/8
- b) 1/16
- c) 3/8
- d) 1/4
- A BLOWER WITH AN EXTERNAL STATIC PRESSURE OF .55″ WC IS CONNECTED TO A 70 FT. LONG DUCT. THE SYSTEM INCLUDES (WITH CORESPONDING PRESSURE DROPS) REGISTERS AND GRILLS (.03″ WC EACH), A COOLING COIL (.15″ WC) AND FILTER (.10″ WC). WHAT IS THE TOTAL AVAILABLE STATIC PRESSURE REMAINING FOR SIZING THE DUCT?
- a) .15″ WC
- b) .17″ WC
- c) .30″ WC
- d) .24″ WC
- WHAT IS THE VELOCITY OF 1400 CFM OF AIR IN A DUCT MEASURING 12″ X 30″?
- a) 467 FPM
- b) 560 FPM
- c) 3.8 FPM
- d) 360 FPM
- A system desIgned to shut off the gas supply to the burners if the oxygen in the surrounding atmosphere is reduced to a predetermined level is called a ___________
- a) carbon dioxide detector
- b) oxygen depletion shutoff system
- c) automatic shut of valve
- d) air regulator system
- A 75,000 BTUH (INPUT RATING) 80% AFUE FURNACE HAS A TEMPERATURE RISE OF 45-DEGREES. WHAT IS THE CFM?
- a) 1667
- b) 1212
- c) 1515
- d) 1175
- Appliances installed on roofs greater than ______ feet high must have a permanent means of access.
- a) 18
- b) 20
- c) 16
- d) 24
- A fire damper install at a 2-hour fire rated wall shall have a minimum rating of _______ hours
- a) 2
- b) 1.5
- c) 3
- d) 1
- Shield plates placed on studs to protect gas piping shall extend _____ inches to each side of the stud.
- a) 1.5
- b) 3
- c) 4
- d) 2
- The minimum diameter of a close dryer duct shall be ______ inches
- a) 6
- b) 5
- c) 3
- d) 4
- A location that cannot be accessed without damaging permanent parts of a building is called a/an _____ location
- a) concealed
- b) assessable
- c) inaccessible
- d) ready access
- Screens used to protect intake openings for ventilation may not have a mesh less than____ inch.
- a) 1/16
- b) 1/2
- c) 1/8
- d) 1/4
- THE MINIMUM INSULATION R-VALUE FOR REFRIGERANT LINES FOR A RESIDENCE IS ____.
- a) R-3
- b) R-2
- c) 5-5
- d) R-4
- Close dryers exhausting more than ____ cfm must be provided with make-up air
- a) 150
- b) 100
- c) 200
- d) 75
- Which of the follow shall not share a type I hood
- a) charcoal grille
- b) griddle
- c) deep fat fryer
- d) pzza oven
- Underfloor accesses must be a minimum 22 inches high by _______ inches wide
- a) 30
- b) 24
- c) 28
- d) 36
- Closets containing close dryers must have a make up air opening not less than ____ square inches
- a) 75
- b) 100
- c) 150
- d) 50
- Grease ducts in enclosures shall have a clearance of ________ inches to construction of non-combustible gypsum attached to non-combustible structures
- a) 18
- b) 12
- c) 6
- d) 3
- Which of the following heating systems must have its efficiency posted on a certificate placed on or inside the electrical distribution panel of new residential construction
- a) Electric baseboard
- b) unvented room heater
- c) gas furnace
- d) electric furnace
- A ventilation system in a 20,000 square foot enclosed parking garage shall be capable of producing a minimum of _____ cfm, while full-on.
- a) 10,000
- b) 20,000
- c) 5000
- d) 15,000
- IN ORDER TO SUPPLY OUTDOOR COMBUSTION AIR USING THE TWO OPENING METHOD WITH HORIZONTAL DUCTS, WHAT DUCT SIZE BELOW WOULD BE THE MINIMUM NEEDED TO HANDLE A 140,000 BTUH FURNACE
- a) 3.5″ X 10″
- b) 8.5″ X 10″
- c) 7″ X 10″
- d) 14′ X 10″
- Factory built fireplaces must be listed and labeled according to __________.
- a) UL 348
- b) UL127
- c) UL 187
- d) UL 124
- A single wall oil heat chimney connector shall have ______ clearance from combustibles
- a) 9
- b) 18
- c) 36
- d) 12
- A plastic condensate pan must have a minimum thickness of ______ inch
- a) .0250
- b) .0625
- c) .0375
- d) .0276
- If natural ventilation is used, a building, measuring 3000 square feet, must have a minimum openable area of ______ square feet.
- a) 120
- b) 150
- c) 300
- d) 450
- Duct smoke detectors shall comply with______.
- a) UL 268
- b) UL 181
- c) ASTM 34
- d) NFPA 72
- A 2-inch diameter gas pipe must be purged with an inert gas before opening if it is greater than _____feet long.
- a) all of the above
- b) 30
- c) 50
- d) 40
- Unless protected by approved area smoke detectors, smoke detectosrs are required in the return air duct or plenum on any system with a design capacity greater than _______cfm.
- a) 1500
- b) 2000
- c) 4000
- d) 3000
- IF A CONTRACTOR WORKS ON 15% PROFIT, WHAT WOULD HIS SALES HAVE TO BE TO MAKE $75,000?
- a) $600,000
- b) $112,000
- c) $500,000
- d) $862,500
- A single wall low heat 6-inch diameter chimney connecter shall have a minimum thickness of ______
- a) 22
- b) 16
- c) 26
- d) 24
- The verical distance between the front lower lip of a type I or II hood and the surface of the appliance shall not extend more than ______ feet
- a) 3.6
- b) 4
- c) 2
- d) 3
- Vented wall furnaces shall be located so that a door cannot swing within _____ inches of the air inlets or outlets of such furnace measures at right angles to the openings
- a) 12
- b) 18
- c) 36
- d) 24
- FUEL FIRED APPLIANCES SHALL NOT BE LOCATED IN _______.
- a) BASEMENTS
- b) BEDROOMS
- c) LIVING ROOMS
- d) KITCHENS
- THE VELOCITY OF 250 CFM OF AIR IN A FLEXIBLE, SPIRAL WIRE HELIX CORE DUCT SIZED AT .08″ WC STATIC PRESSURE IS ______.
- a) 500 FPM
- b) 900 FPM
- c) 400 FPM
- d) 750 FPM
- Which of the following is not required for a heat pump installation
- a) load calculation
- b) programmable thermostat
- c) a permit
- d) a means of controlling electric resistance heat from operating when the heat pump can handle the load
- Exhaust outlets that terminate above a roof shall have a discharge outlet not less than ___ inches above the roof surface
- a) 36
- b) 30
- c) 48
- d) 40
- A CUSTOMER MOVES UP FROM AN 8 SEER TO A 13 SEER AIR CONDITIONER. WHAT WOULD HIS YEARLY SAVING BE IF HE WAS PAYING $650 PER YEAR FOR AIR CONDITIONING
- a) $197
- b) $325
- c) $250
- d) $260
- A CEILING HAS A TOTAL U-VALUE OF .07. WHAT IS THE NEW R-VALUE IF R-19 IS ADDED?
- a) 33.28
- b) 32.28
- c) 30.28
- d) 31.28
- The control side of a floor furnace must have a minimum _____inches clearance
- a) 24
- b) 18
- c) 20
- d) 12
- Which of the following must have a flame spread rating no greater than 5 feet when installed in plenums.
- a) pneumatic tubing
- b) wiring
- c) all the above
- d) fire sprinkler piping
- The maximum size unvented gas heater that may be installed in a residential bathroom measuring 1600 cubic feet is________btuh
- a) 8000
- b) 4000
- c) 3000
- d) 6000
- The slope of a 24-foot horizontal grease duct must be at least ___ inch.
- a) 1/8
- b) 1/4
- c) 3/4
- d) 1/2
- If a water level detection device is used in an auxiliary drain pan it must conform to_______.
- a) ASTM 243
- b) UL 508
- c) UL 181
- d) ASI 84
- The vent cap of an oil tank must have a screen mesh no finer than No. _______
- a) 10
- b) 4
- c) 6
- d) 8
- WHAT IS THE DESIGN FRICTION RATE WHEN THE AVAILABLE STATIC PRESSURE FOR THE DUCT SYSTEMIS .36″ WC AND THE RUN WITH THE LONGEST EFFECTIVE LENGTH IS 375 FEET?
- a) .05″ WC
- b) .08″ WC
- c) .15″ WC
- d) .10″ WC
- Passageways in attics shall not be less than _____ inches wide
- a) 24
- b) 20
- c) 30
- d) 22
- AN APPLIANCE THAT REQUIRES 18″ CLEARANCE ON ITS SIDES, MAY HAVE ITS CLEARANCE REDUCED TO ______ IF .024″ SHEETMETAL WITH A 1” VENTILATED AIR SPACE IS USED TO PROTECT THE COMBUSTIBLE SURFACE.
- a) 6”
- b) MAY NOT HAVE CLEARANCE REDUCED
- c) 12”
- d) 9”
- A vertical pipe supplying gas is a________
- a) riser
- b) leader
- c) upright
- d) standpipe
- Copper piping shall not be used if the gas contains more than __ grains of hydrogen sulfide per 100 standard cubic feet.
- a) .3
- b) 3
- c) .5
- d) 6
- Brazing alloys used on gas piping shall not contain more than_____ percent phosphorus
- a) .005
- b) .5
- c) 5
- d) .05
- Duct insulation installed within ____inches of a type I hood shall be noncombustible of be listed for the application
- a) 18
- b) 6
- c) 12
- d) 24
- The minimum distance between the cooking surface and a grease filter serving burners with flames is _____ feet
- a) 1
- b) 3.5
- c) .5
- d) 2
- The minimum gage for a 14 inch round galvanized air duct is ___.
- a) 30
- b) 28
- c) 26
- d) 24
- FOR A BUILDING TO BE MAINTAINED AT 70 F, HOW MANY BTUH ARE REQUIRED TO OFFSET 300 CFM OF 20 F OUTDOOR VENTILATION?
- a) 16,500
- b) 6,600
- c) 6,000
- d) 1.400
- The maximum operating pressure of LP gas systems shall not exceed ____ unless the building or area is constructed according to NFPA 58, Chapter 10
- a) 10
- b) .5
- c) 5
- d) 20
- THE AMERICANS WITH DISABILITIES ACT APPLIES TO ALL EMPLOYERS WHO HAVE _______ OR MORE EMPLOYEES
- a) 25
- b) 15
- c) 50
- d) 10
- Flexible air ducts______.
- a) shall not be limited in length
- b) shall be limited to 14 feet in length
- c) shall be labeled 181-B
- d) May convey air at up to 275 degrees
- The minimum allowable HSPF rating of an air-cooled residential heat pump is _________
- a) 7.0
- b) 8.2
- c) 6.8
- d) 7.7
- A 500 SQUARE FOOT CONFERENCE ROOM REQUIRES _______CFM OF OUTDOOR VENTILATION
- a) 125
- b) 250
- c) 75
- d) 150
- When mechanically ventilating a 1500 square foot conference room in an office building, how many CFM of outdoor air are required?
- a) 375
- b) 1000
- c) 50
- d) 3000
- Access points for inspecting and servicing fire dampers shall be labeled FIRE DAMPER with letter no less than _____ inch/s high
- a) .5
- b) .75
- c) 2
- d) 1
- Unless protected from vehicle impact, appliances shall be installed a minimum ______ feet above the floor of a private garage
- a) 6
- b) 5
- c) 8
- d) 9
- Cleanouts located on horizontal grease ducts shall be placed not more than ____feet apart
- a) 100
- b) 15
- c) 20
- d) 10
- Unless otherwise approved, ducts shall not be installed within ____ inches of earth.
- a) 4
- b) 3
- c) 5
- d) 6
- THE DISTANCE FROM A METER TO A NATRUAL GAS WATER HEATER (40,000 BTUH) IS 30 FEET. 20 FEET FURTHER DOWN THE LINE IS A FURNACE (120,000 BTUH). WHAT IS THE MINIMUM PI[E SIZE THAT MUST BE USED BETWEEN THE WATER HEATER AND FURNACE? (PRESSURE LESS THAN 2 LBS, PRESSURE DROP = .05)?
- a) 1/2″
- b) 3/4″
- c) 1″
- d) 3/8″
- A gas regulator that reduces incoming pressure between .5 and 5 psig to a lower pressure is called a __________.
- a) low pressure regulator
- b) service entrance regulator
- c) high pressure regulator
- d) medium pressure regulator
- A HEAT PUMP IN A RESIDENCE MUST BE CONTROLLED BY WHICH OF THE FOLLOWING?
- a) A PROGRAMABLE THERMOSTAT
- b) A DEVICE TO PREVENT SUPPLEMENTARY HEAT FROM COMING ON IF HEAT PUMP CAN HANDLE THE LOAD ALONE
- c) A DEVICE THAT ALLOWS SUPPLEMENTARY HEAT OPERATION DURING DEFROST CYCLES EXCEEDING 15 MINUTES
- d) A FOSSIL FUEL KIT
- When bending metallic gas pipe, the inside radius shall not be less than _____ times the diameter
- a) 6
- b) 10
- c) 5
- d) 25
- THE LARGEST A BORED HOLE MAY BE IN A 2′ x 9.5″ joist is
- a) 3.14″
- b) 3.31″
- c) 3″
- d) 2.85″
- When aluminum foil is used as a vapor retarder for duct insulation it must be minimum
_____ mils thick
- a) 4
- b) 2
- c) 1
- d) 6
- A label shall be affixed to the gas appliance with all the following information except _______
- a) BTUH rating
- b) type of fuel used
- c) manufacture date
- d) minimum clearances
- Exhausted environmental air must be _____ feet from mechanical intakes
- a) 12
- b) 8
- c) 3
- d) 10
- THE MAXIMUM BTUH RATING OF AN UNVENTED GAS HEATER INSTALLED IN A 15 X 20 ROOM WITH 8 FOOT CEILINGS IS (infiltration rate is greater than .40 ACH)?
- a) 48,000
- b) 40,000
- c) 24,000
- d) 6,000
- Liquid adhesive used on air filters shall have a flsh point no lower than ______ degrees F
- a) 230
- b) 275
- c) 250
- d) 325
- Unless welded or placed in a ventilated shaft, the maximnm operating pressure of gas piping in a residence shall not exceed _______ psig
- a) .5
- b) 10
- c) 2
- d) 5
- Duct lining shall be interupted _____ inches downstream of a duct heater
- a) 6
- b) 12
- c) 10
- d) 4
- TWO NATURALLY VENTILATED APPLIANCES WITH A COMBINED CAPACITY OF 130,000 BTUH ARE CONNECTED TO A COMMON B-VENT, 18′ HIGH WITH TWO 90-DEGREE ELBOWS. WHAT SIZE COMMON VENT SHOULD BE USED?
- a) 5″
- b) 7″
- c) 4″
- d) 6″
- Shield plates on studs must be a minimum ____ – inch thick
- a) .087
- b) .025
- c) .075
- d) .062
- A floor furnace shall be placed such that a drapery can be no nearer than ______ to the register of the furnace
- a) 18
- b) 12
- c) 6
- d) 8
- Corridors are generaly not permitted to be used as return ducts, however the hallway of a tenant space ______ square feet or less may be used for return air.
- a) 1200
- b) 500
- c) 750
- d) 1000
- Where holes or notches for gas tubing are less than 1.5 inches from the nearest edge of a wood stud, they must be protected by metal shields not less than ____inch thick.
- a) 1/8
- b) 1/32
- c) 1/16
- d) 1/4
- The minimum cross-sectional dimension of a combustion air duct shall be ________ inches
- a) 3
- b) 8
- c) 4
- d) 6
- The highest point of an attic must be at least ___inches in order to be used as a source for combustion air
- a) 28
- b) 30
- c) 24
- d) 36
- A gas line serving a grill may be installed a minimum ______ inches as long as it is approved and not susceptible to physical damage
- a) 8
- b) 12
- c) 6
- d) 16
- Which rooftop appliance does not require guardrail protection?
- a) one located 3 feet form roof edge
- b) one located 6 feet from roof edge
- c) one located 4 feet from roof edge
- d) one locate 8 feet from roof edge
- When obtaining combustion air from an attic, a minimum 26 gage galvanized sheet metal sleeve must be used and extended ________ inches above the joists and insulation
- a) 6
- b) 2
- c) 8
- d) 4
- A HOUSE HAS A HEAT LOSSS OF 48,000 BTUH AT 20-DEGREE OUTDOOR TEMPERATURE. WHAT IS THE HEAT LOSS AT 40-DEGREE OUTDOOR TEMPERATURE?
- a) 18,000 BTUH
- b) 124,000 BTUH
- c) 19,200 BTUH
- d) 28,800 BTUH
- Duct insulation shall have the R value printed every_________ inches
- a) 60
- b) 36
- c) 48
- d) 24
- A CONTRACTOR PAYS $750 FOR A FURNACE PLUS 7% TAX. WHAT WOULD HIS SALES PRICE BE IF HE WISHED TO MAKE 30% GROSS PROFIT?
- a) $1028
- b) $1146
- c) $1043
- d) $975
- A 30′ X 8′ PARTITION (2 X 4 STUDS, GYPSUM ON BOTH SIDES, NO INSULATION) SEPARATES TWO ROOMS HAVING A TEMPERATURE DIFERENCE OF 20 DEGREES. WHAT IS THE WINTER HEAT LOSS THROUGH THE PARTITION?
- a) 3,535 BTUH
- b) 15,360 BTUH
- c) 1,500 BTUH
- d) 2,609 BTUH
- Which of the following gas piping materials shall not be used in exterior locations or underground
- a) steel
- b) plastic
- c) brass
- d) aluminum
- This question eliminated
- a) ?
- b) ?
- Gas piping installed underground beneath buiding may not be incased in _________.
- a) cement
- b) steel pipe
- c) plastic pipe
- d) wrought iron conduit
- Floor registers must support ______lbs consentrated load on a 2-inch disk applied at its most critical area
- a) 100
- b) 250
- c) 150
- d) 200
- AN AIR CONDITIONER HAS HIGH SUCTION AND A LOW HEAD PRESSURES. WHAT WOULD BE A LIKELY CAUSE?
- a) DIRTY CONDENSER COIL
- b) DIRTY FILTERS
- c) CLOGGED METERING DEVICE
- d) BAD OR WEAK COMPRESSOR VALVES
- When cutting threads, a 3/4-inch pipe shall have approximately _______ treads cut
- a) 12
- b) 11
- c) 10
- d) 13
- Type I grease ducts shall have a clearance of _____ inches to combustible construction
- a) 18
- b) 3
- c) 6
- d) 12
- Grease ducts shall provide an air velocity not less than _______ feet per minute
- a) 400
- b) 750
- c) 250
- d) 500
- IF PROTECTION FROM VEHICLE IMPACT IS NOT PROVIDED, APPLIANCES INSTALLED IN PRIVATE GARAGES MUST BE INSTALLED _____ FEET ABOVE THE FLOOR.
- a) 7
- b) 6
- c) 8
- d) 5
- THE MAXIMUM HORIZONTAL LENGTH OF A SINGLE WALL CONNECTOR IS ______% OF THE HIEGHT OF THE CHIMNEY OR VENT.
- a) 50
- b) 100
- c) 75
- d) 150
- Condensate piping must no be less than _____ inch diameter
- a) 3/4
- b) 1/2
- c) 5/8
- d) 1
- The unthreaded portion of a gas piping outlet shall not extend less then ______ through a slab floor
- a) 1.5
- b) 3
- c) 2
- d) 1
- A DOUBLED UP STUD IN A LOAD BEARING WALL MAY HAVE A HOLE BORED UP TO ______% OF IT DEPTH
- a) 25
- b) 40
- c) 60
- d) 15
- A vent is not _____
- a) site made
- b) a passageway for carrying combustion products
- c) factory made
- d) listed and labeled
- A HOUSE HAS A HEATING LOAD OF 48,000 BTUH. HOW MANY CFM ARE REQUIRED FOR A ROOM WITH A HEAT LOAD OF 5200 BTUH, USING A FURNACE WITH A 1200 CFM BLOWER?
- a) 468
- b) 112
- c) 130
- d) 1112
- A home must be provided with a space heating system capable of maintaining a minimum indoor temperature of _____ degree at a point 3 feet above the floor level on a design heating day
- a) 78
- b) 70
- c) 75
- d) 68
- An appliance that causes a positive vent pressure and produces excessive condensation in the vent is a Category ______ appliance
- a) II
- b) IV
- c) I
- d) III
- Pressure sensitive tapes used on flexible ducts shall be lableled as conforming to ______
- a) UL 181 A
- b) UL 181-FX
- c) UL 181 A-P
- d) UL 181 B
Answers
- c 404.Tracer
- b Table 403.3
- c section 406 (5 x test pressure)
- a section 601
- d section 914
- b section 401
- c Chapter 2 Definitions
- d section 709 ( 6 x10 = 60 sq. in., 60/.75 = 80 sq. in.)
- d Chapter 2 definitions of “regulator, medium pressure”
- d section 802 imc
- d section 701 imc (NOT IN THE NEWER CODES)
- d section 507 (300 X 5 ft = 1500 cfm)
- a section 505.3 imc ( exception includes PVC in some cases
- b section 304.9 ifgc (150,000/1000 = 150, 150 x.35 = 52.5)
- c section R403 energy code, 4 cfm per 100 sq. ft.
1500 sq. ft. / 100 = 15
15 x 4 =60 cfm
- c 404.17.1 Limitations. IFGC
- c 411.1.3.1 gas code
- d 409.5.1gas code IFGC
- a section 303.7 IMC
- a 404.5 gas code
- d Table 305.4 IMC
- b definitions-listed
- b section 507 IMC
- c Chapter 2 definition “recovered refrigerant” mech code
- c SECTION 503.10.9 gas code LENGTH OF VENT CONNECTOR, GAS CODE
- c section 506.3.1.1 IMC
- b 302 MECH CODE
28 a TABLE 503.4 gas code
- a 1102. mech code
- b 1,000,000/140,000 = 7.143 gals
7.143/.80 = 8.928 gals @ 80% efficiency
8.928 x $1.25 = $11.60
- c Table 415.1 gas code
- a section 307.2.3 IMC
- a Manual D rectangular to round tables or use duct calculator.
- c 411.1.3.3 gas code
- a section 914 IMC
- C section R403 energy code
- d 404.17.1 gas code
- a section 504 IMC ( 35 feet minus 5 feet for each 90 degree bend)
Note: some older codes allow for a max of 45 feet with a penalty of 10 feet for each 90 degree bend
- a section 918 IMC( 80000/1000 =80, 80 x 2″ = 160 square inches)
- c Chapter 2, definitions gas code
- a See sec. 304.5.1 gas code 75000/1000 = 75
75 x 50 = 3750 cubic feet
- a 303 gas code, room must be 12 times larger than the appliance. Note this provision is not in all codes
- b 305 gas code
- d. section 504.9.3 IMC
- b section 301.9 imc
- c section 1305 IMC
- d .55 – .03- .03 – .15 -.10 = .24′ wc
- b vel – cfm/ area in sq. ft.
12″ x 30″ = 360 sq. in.
360 sq. in / 144 = 2.5 sq. ft.
- b chapter 2 definitions, gas code
- b CFM = BTUH / (TR x 1.1)
bthu = 75,000 x .80 = 60,000
- c 306.5 mech code
- b Table 607.3.2.1 imc
- c 404 gas code
- d section 504.9 IMC
- a Chapter 2 mech code “concealed location” definition
*56. d Table 401.5 IMC
- a section 403 energy code
- c section 504 IMC
- a Section 507 IMC( charcoal grille is extra heavy duty)
- a section 306 IMC
- b section 504 IMC
- c section 506 Grease duct enclosure
- c section R401 energy code
- d section 404 IMC (20,000 x .75 = 15,000)
- c 304 IMC, 140,000/2000 = 70 square inches, 7 x 10 =70 square inches(Gas Code)
- b section 903 IMC
- b Table 803.10.6 IMC
- b section 307
- a section 402 IMC (3000 X .04 = 120)
- a section 606 IMC
- a table 406.7.1 gas code
- b section 606 IMC
- c $75,000/.15 = $500,000
- d Tabel 803.9(1) IMC
- b section 507 IMC
- a section 909 IMC
- b 303 mechanical code
- a use friction chart or ductulator
- b section 403 energy code
- d Section 506 IMC
- c 8/13 = .615
.615 x 650 = 400 op cost of new a/c
650- 400 = $250 savings
- a Only R values can be added or subtracted, therefore, convert the U value to R value 1/.07= 14.28
add R 19 + R 14.28 = R 33.28
- b section 910 IMC
- c section 602 IMC
- d 303.3 exception 3, and 304.5.1 gas code
- d section 506 IMC ( 1st Convert 24 feet to incese, 24’ X 12” = 288 inches, next 2% X 288 INCHES = 5.76 INCHES or .02 x 288” = 5.76”)
- b section 307 IMC
- b section 1305 IMC
- d .36 x100/375 = .096 (rounded to .10) manual d
- d section 306 IMC
- a Table 308.6
- a Defintions, gas code
- a section 403 IFGC
- d section 403 IFGC
- a section 506 IMC
- d Table 507 IMC
- a Table 603.4
- a 70F-20F = 50F TD
BTUH = CFM x 1.1 x TD
= 300 x 1.1 x 50
- d 402 gas code
- b NASCLA business book or look up ADA
- a section 603 IMC (flexible connectors must be limited to 14 feet, not ducts)
- d Table C403.2.3 (2) energy code
- a Table 403.3.1.1 mech code
table assumes 50 people /1000 sq ft
Therefore 25 people would occupy 500 sq ft
25 people x 5 cfm/person = 125 cfm
- a Tablle 403.3 IMC (1500/1000 = 1.5, 1.5 x 50 people = 75 people, 75 x 5 cfm = 375 cfm)
- a section 607 IMC
- a section 304 IMC
- c section 506 IMC
- a Section 603 IMC
- b See “longest length method” in gas code appendix
- d section 202 IFGC
- b 2012 energy code only
- a 405 gas code
- a 302 mech code
- b section 604 IMC
- c 301 gas code
- d section 501 IMC
- a 304.5.1 gas code
15 x 20 x 8 = 24,000 cubic ft.
24,000 / 50 = 48
48 x 1000 = 48,000 btuh
- d section 605 IMC
- d section 402 IFGC
- a section 604 IMC
- d Use Table 504.3(1), IFGC, Remember to use the 15 ft. height not 20 ft.
- d section 305 IMC (2009-2012 says .0575)
- b section 910 IMC
- d section 601 IMC
- c 404.5 gas code
- a section 305.3.1 IFGC
- b section 701 IMC
- a 404.9.1 gas code
- d section 304 IMC, says “within” 6 feet
- a section 701 (2006 IMC)
- d 48,000 btuh / 50 degree TD = 960 btuh heat loss per degree TD
new TD 70F-40F = 30
30 degree TD x 960 BTUH per degree TD = 28,800 btuh
- b section 604 IMC
- b $750 x .07 = $52.50
$750.00 + 52.50 = $802.50
100%-30% = 70% 0r .70
802.50/.70 = $1146.42
- c still air surface = .68
gypsum = .45
air space = .91
gypsum = .45
still air surface = .68
Total R = 3.17
U = 1/3.17 = .315
wall is 240 square feet (30 x 8)
BTUH = area x U x td
240 x .315 x 20 = 1512 (close enough)still air surface = .68
- d 403 gas code
- This question eliminated
- a 404 gas code
- d section 603 IMC
- d see any service manual
- c Table 403.9.2 gas code
- a section 506 IMC
- d section 506 IMC
- b 305 gas code
- c 503.10._ gas code
- a section 307 IMC
- c 404 gas code
- c 302 mech code
- a see definition “vent”, gas code
- c Room cfm = HF X room heat lose
HF factor = 1200/48,000
HF= .025
Therefore: .025 x 5200 = 130 cfm
- d section 309 IMC
- b Gas Code definitions “vented appliance categories”
- a Section 603 IMC