EMS HVAC practice exam BACK TO HOME
Based on 2018 and 2021 IMC and IFGC
- A tracer wire buried with plastic gas piping shall be minimum ___AWG.
- 16
- 14
- 18
- 20
- The minimum ventilation rate for living area of a residence is the greater of 15 cfm per person or ____ air changes per hour.
- .5
- .35
- .40
- 1
- When using a test pressure of 10 psig, the test gauge shall not be capable of reading pressures greater than_____PSIG .
- 100
- 80
- 50
- 75
- The use of gypsum boards to for plenums shall be limited to systems where the temperature does not exceed _______ degrees F and the temperature of the conveyed air is kept above the dew point.
- 125
- 110
- 250
- 95
- A sauna room shall have a vent opening above the door at least 4 inches by ____ inches.
- 6
- 12
- 10
- 8
- A house with indoor temperature of 70F located in an area with a 10F outdoor design temperature has a heat loss of 48,000 BTUH. What is the heat loss at 40 F outdoor design temperature?
- a. 40,000 BTUH
- b 28,000 BTUH
- c 24,000 BTUH
- d 36,000 BTUH
- Gas piping shall be labeled at intervals not exceeding ______ feet.
- a) 8
- 5
- 4
- 3
- A JOINT OBTAINED BY THE JOINING OF METAL PARTS WITH METALLIC MIXTURES OF ALLOYS WHICH MELT AT 1050 DEGREES F, IS CALLED A __________ JOINT.
- WELDED
- MECHANICAL
- BRAZED
- SOLDERED
- If an 6″ X 10″ duct is terminated with a metal louver (75% free area), the louver must be a minimum _____ square inches.
- 90
- 60
- 120
- 80
- A gas regulator that reduces incoming pressure between .5 and 5 psig to a lower pressure is called a __________.
- service entrance regulator
- low pressure regulator
- high pressure regulator
- medium pressure regulator
- Unless otherwise specified by the manufacturer, vents shall terminate not less than ______feet above the highest connected appliance.
- 12
- 10
- 8
- 5
- When obtaining combustion air from a crawl space, the free area of the crawl space vent to the outside must be a minimum ________ the size of the combustion air opening.
- 4 times
- 5 times
- 3 times
- 2 times
- A type I hood, 5 foot long, wall mounted canopy, serving medium-duty appliances shall have a minimum capacity of _____ CFM.
- 1000
- 2500
- 500
- 1500
- Downdraft kitchen exhaust ducts may be constructed of______.
- all of the above
- sheet metal
- aluminum
- PVC
- When combustion air is mechanically forced into a room, a minimum rate of ______ cfm per 1000 btu/h of combined input rating of all installed appliances must be supplied.
- .35
- 0
- .25
- .40
- The maximum cfm of duct leakage allowed with a air handler in place for a 1500 square foot home with .1 inch w.c. is____.
- 75
- 150
- 60
- 80
- Plastic pipe shall not be operated at pressures greater than ______ psig for LP gas
- 100
- 15
- 30
- 10
- Semi-ridgid metallic tubing used as appliance connectors shall not exceed ___ feet
- 8
- 3
- 6
- 5
- For other than appliances installed in fireplaces, a gas shutoff valve shall be located within ___feet of the appliance
- 3
- 4
- 10
- 6
- Appliance pits greater than 12 inches deep shall be lined with masonry extending ___inches above the adjoining grade
- 4
- 2
- 3
- 6
- Gas piping may be joined in concealed locations using which of the following methods?
- brazing
- compression fittings
- unions
- d) swing joints
- 1/2″ copper tubing must be supported a minimum of _______ feet when installed horizontally.
- 4
- 10
- 8
- 12
- Equipment, appliances or material included in a list published by a nationally recognized testing laboratory concerned with product evaluation and states that the above item meets recognized standards is said to be _____________ .
- approved
- listed
- certified
- tested
- A type I hood is not required for _______.
- griddles
- hot dog cookers
- fryers
- broilers
- REFRIGERANTS REMOVED FROM A SYSTEM IN ANY CONDITION WITHOUT NECESSARILY TESTING OR PROCESSING THEM ARE CALLED___________.
- RECYCLED REFRIGERANTS
- RECIEVED REFRIGERANTS
- RECOVERED REFRIGERANTS
- RECLAIMED REFRIGERANTS
- THE MAXIMUM ALLOWABLE HORIZONTAL LENGTH OF A CATEGORY I APPLIANCE SINGLE WALL VENT CONNECTOR IS _______% OF THE HEIGHT OF THE VENT
- 50
- 25
- 75
- 100
- A commercial stainless steel grease duct must be constructed of ______ gage thickness
- 20
- 14
- 18
- 16
- A NON LOAD BEARING STUD MAY BE NOTCHED ______% OF ITS
- 30
- 40
- 25
- 15
- CATEGORY I GAS EQUIPMENT MAY BE VENTED WITH WHICH OF THE FOLLOWING TYPES OF VENTS?
- ALL THE ABOVE
- CHIMNEY WITH CLAY LINER
- TYPE B
- SINGLE WALL METAL
- RECLAIMED REFRIGERANTS SHALL NOT BE REUSED IN A DIFFERENT
OWNERS EQUIPMENT UNLESS TESTED AND FOUND TO MEET THE PURITY
REQUIREMENTS OF
- ARI 700
- ASTM A53
- NFPA 54
- ASHRAE 34
- IF A GALLON OF OIL CONTAINING 140,000 BTU’S SELLS FOR $1.25,
HOW MUCH WILL 1,000,000 BTU’S COST WHEN USED IN AN 80% AFUE OIL
FURNACE
- $8.93
- $11.16
- $14.00
- $12.78
- For 3/4 inch steel gas pipe hangers or supports shall be spaced not farther than _____feet apart
- 10
- 4
- 8
- 6
- An auxiliary drain pan must have a minimum depth of ____ inche/s
- a) 1.5
- 1
- 25
- 2
- A 12″ ROUND DUCT HAS A RECTANGULAR EQUIVALENT OF
- 16 X 8
- 15 X 8
- 14 X 8
- 17 X 8
- GAS APPLIANCE CONNECTORS SHALL NOT PASS THROUGH ANY OF THE FOLLOWING EXCEPT
- WALLS
- APPLIANCE HOUSINGS
- FACTORY BUILT FIREPLACES
- FLOORS
- Sauna heaters shall have a thermostat that limits the room temperature to _______ degrees F
- 194
- 144
- 114
- 120
- The minimum R value of duct insulation installed in areas other than the conditioned space or attics is _________
- R 5
- R 6
- R 8
- R 4
- ___________ piping may only be used for gas piping outside and underground.
- Aluminum
- Copper
- Steel
- Plastic
- The maximum length allowed for a 4 inch dryer duct with two 90 degree bends is ______ feet
- 25
- 35
- 30
- 40
- The minimum return opening to an 80,000 btuh (output rating) forced air furnace shall be _____ square inches.
- 160
- 80
- 140
- 100
- A location that cannot be accessed without damageing permanent parts of a building is called a/an _____ location
- inaccessible
- assessible
- concealed
- ready access
- AN APPLIANCE RATED AT 75,000 BTUH INPUT MUST BE PLACED IN A ROOM CONTAINING A MINIMUM ______ CUBIC FEET WITHOUT THE INTRODUCTION OF OUTDOOR COMBUSTION AIR.
- 3750
- 7500
- 1500
- 75000
- A FUEL FIRED FURNACE, MEASURING 22 CUBIC FEET MUST BE
PLACED IN A ROOM GREATER THAN __________ CUBIC FEET IF IT IS NOT
APPROVED FOR CLOSET INSTALATION
- 264
- 352
- 220
- 564
- he ignition source of an appliance shall be elevated not less than _____ unless it is listed as flammable ignition resistant
- 6 feet
- 18 inches
- 4 feet
- 24 inches
- Transition ducts used to connect commercial dryers to exhaust duct shall be limited to ___ feet in length
- 4
- 3
- 6
- 8
- A label shall be affixed to a gas appliance with all the following information except _______
- BTUH rating
- manufacture date
- type of fuel used
- minimum clearances
- The miminum size supply line to an oil furnace shall be _______ inch.
- a) 1/8
- 1/16
- 3/8
- 1/4
- A BLOWER WITH AN EXTERNAL STATIC PRESSURE OF .55″ WC IS CONNECTED TO A 70 FT. LONG DUCT. THE SYSTEM INCLUDES
REGISTERS AND GRILLS (.03″ WC EACH), A COOLING COIL (.15″ WC) AND FILTER (.10″ WC). WHAT IS THE TOTAL AVAILABLE STATIC PRESSURE REMAINING FOR SIZING THE DUCT?
- .15″ WC
- .17″ WC
- .30″ WC
- .24″ WC
- WHAT IS THE VELOCITY OF 1400 CFM OF AIR IN A DUCT MEASURING 12″ X 30″?
- 467 FPM
- 560 FPM
- 8 FPM
- 360 FPM
- A system designed to shut off the gas supply to the burners if the oxygen in
the surrounding atmosphere is reduced to a predetermined level is called a
___________
- carbon dioxide detector
- oxygen depletion shutoff system
- automatic shut of valve
- air regulator system
- A 75,000 BTUH (INPUT RATING) 80% AFUE FURNACE HAS A TEMPERATURE RISE OF 45-DEGREES. WHAT IS THE CFM?
- 1667
- 1212
- 1515
- 1175